Customization: | Available |
---|---|
Type: | Animal Inhalation Exposure System |
Syringe: | / |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Control System | Controller | 1. Control mode: cavity pressure PID mode |
2. Working status indicator prompt function | ||
3.Communication mode s,up,port WIFI, bluetooth, remote control support | ||
4.Control the flow rate 0-50L/min, dilution 0-50L/min,sampling flow sampling flow range: 0~3L/min; sampling time error: <1S | ||
5.Flow control accuracy ± 0.3% + ± 0.5% of reading | ||
6. The main control system can be used for both nose and mouth/large animal exposure | ||
7. Monitoring of expandable inhalation volume | ||
Operating Software | 1. Comply with FDA 21 CFR Part 11 specification | |
2. Automatic concentration adjustment | ||
3. Timing automatic sampling | ||
4. Wireless remote multiple exposure equipment centralized control | ||
5. Provide up to 16 real-time, historical data records | ||
6. 15 abnormal event alarm reminders | ||
7. Data export CVS, PDF format | ||
Concentration Detector | Measuring range 0.001mg/m3~250g/m3 with real-time online sampling of liquid aerosol and automatic adjustment of experimental dose concentration to target value | |
Concentration Control | 1. Control mode: automatic and manual free switching | |
2. Control uniformity: (concentration measurement reference 712) | ||
When the concentration setting value is < 250mg/m3, the error is less than ± (set value × 10%) When the concentration setting is between 250mg/m3 and 500mg/m3, the error is less than (set value × 8%) When the concentration setting value is > 500mg/m3, the error is less than ± (set value × 5%) | ||
Environmental Monitoring Module | Environmental Monitoring Module | 1. Integrated design, easy to deploy |
2. Small size, direct measurement of exposed mouth | ||
3. Measurement parameters: O2; CO2; temperature; humidity; pressure, expandable | ||
4. Parameter index: oxygen concentration: 1~25%, carbon dioxide: 0~5% temperature: range -40~125°C accuracy ±0.2°C, humidity: 0~100%RH Accuracy ±1%, monitoring internal and external cavity pressure, pressure difference range -1000~1000Pa | ||
Generator Section | Liquid Aerosol Generator | 1.MMAD: 1~4μm; GSD: 1.5~3.0 |
2. Flow rate: 0-30L/min | ||
3. Pressure range: 100-600Kpa | ||
4. Guaranteed long-term stable continuous output | ||
Liquid Aerosol Generator | 1. Particle size occurs MMAD 1~4μm GSD1.5~3 | |
2. Flow rate occurs: 3-10L/min | ||
3. Pressure range: 100-500Kpa | ||
4. Guaranteed long-term stable continuous output | ||
Dust Aerosol Generator | 1. Particle size: <0.1μm~100μm | |
2. Intake requirement: 1~5bar (0.1~0.5Mpa) | ||
3. Continuous running time: 10min~600h | ||
4. Export dust mass flow: 0.3~15g/h | ||
5. Flow range: 0-20L/min | ||
6. Size: 230*230*230 mm | ||
7. Weight: 6 kg | ||
Exposure Device | Oral and Nasal Exposure Cabinet | 1. Exposure cabinet 5-stage filtration system, negative pressure PID control |
2. Monitoring filter replacement alarm | ||
3. Imported fan Low noise | ||
4. With protective lighting function | ||
5. Size: 1000mm * 1030mm * 2035mm | ||
Mouth and Nose Exposure Tower | 1. Material: SUS 316L | |
2. Test capacity: 12 supports per layer, stackable extension | ||
3. Patented cavity design concentration distribution is more stable and uniform | ||
4. Compatible with a variety of liquid, dust aerosol and cigarette generators | ||
Holder | 1. Using medical PC material, caliber 26.7MM, can be used for high temperature sterilization | |
2. Quick lock design for easy animal handling and fixing | ||
3. Back heat dissipation design to avoid heat accumulation and damage to animals | ||
4. Excreta diversion trough design to improve the comfort of animals during the experiment | ||
Exhaust Gas Treatment Device | Exhaust Gas Treatment Device | 1. Five-stage filtration, filtration efficiency ≥99.97% |
2. Fan speed: 0~3779 | ||
3. PID control adjusts fan speed in realtime | ||
4. Filter pressure difference range: -1000~1000Pa, real-time display fan speed pressure, filter alarm |